Customer Support

Hotline 021-5807-3899

Product Detail

U42 Clamp-on & Insertion Ultrasonic Liquid Flowmeter

Brand VorTek
Model U42
Series Ultrasonic
Detail
Documents
Multimedia
Program


Performance

Flow Range . . . . . . . . . . . . . . . .±0.03 ft/s ~ ±40 ft/s (±0.01 m/s ~ ±12 m/s)

Accuracy . . . . . . . . . . . . . . . . . .±1% of reading (0.5% according to calibration)

Repeatability . . . . . . . . . . . . . . . .0.15% of reading

Linearity . . . . . . . . . . . . . . . . . . .±0.5%
Pipe Size . . . . . . . . . . . . . . . . . .1”to 200”(25 mm to 5000 mm)
Fluid . . . . . . . . . . . . . . . . . . . . . .Clean liquids with little to no air bubbles or particles


Function

Outputs . . . . . . . . . . . . . . . . . . .Analog output: 4 ~ 20 mA, max load 750Ω.

Pulse output: . . . . . . . . . . . . . . .0 ~ 9999 Hz, OCT, (min. and max. frequency is adjustable)

Relay output: . . . . . . . . . . . . . . .SPST, max 1 Hz, (1 A @ 125 VAC or 2 A @ 30 VDC)

Communication . . . . . . . . . . . . .RS-232 & RS-485 Modbus

Memory . . . . . . . . . . . . . . . . . . .SD card (Max 4GB)

Power Supply . . . . . . . . . . . . . . .90 to 245 VAC, 48 to 63 Hz, or 10 to 36 VDC

Display . . . . . . . . . . . . . . . . . . . .240*128 back lit LCD

Transmitter Temperature . . . . . . .-40°F~ 140°F(-40°C~ 60°C)

Humidity . . . . . . . . . . . . . . . . . .Up to 99% RH, non-condensing


Physical

Transmitter . . . . . . . . . . . . . . . . .Aluminum, IP65

Transducers . . . . . . . . . . . . . . . .IP68

. . . . . . . . . . . . . . . . . . . . . . . . . .Encapsulated design

. . . . . . . . . . . . . . . . . . . . . . . . . .Double-shielded transducer cable

. . . . . . . . . . . . . . . . . . . . . . . . . .Standard/maximum cable length:

. . . . . . . . . . . . . . . . . . . . . . . . . .30 ft / 100 ft (9 m / 30 m)


SonoPro®-Commercial-Series-Ultrasonic-Flow-Meter-(Model-U42)-Brochure.pdf